Cost Function for Nanofiltration
The original cost function (A1) is as follows:
This function has as its variable (x) which is the capacity of the plant in m3 / d (cubic meters per day). The conversion from units to L / s is performed:
Additional modifications to this function correspond to the correction of costs per year, with the CCI ENR index for 2013, to obtain A3. Then part B2 related to the elasticity index is added. This is done in the same way as explained in the article Cost functions — General.
Based on the above, the following is the function obtained:
Share
Bibliography
-
Review of cost versus scale: water and wastewater treatment and reuse processes
Guo, T., Englehardt, J., & Wu, T.
2013
Information on the cost of potentially useful unit treatment processes for the direct reuse of drinking water versus system capacity
References
- Description of the nanofiltration process https://www.sciencedirect.com/topics/chemical-engineering/nanofiltrat…