Cost Function for Nanofiltration

Cost Functions

The original cost function (A1) is as follows:

Función de costo para nanofiltración (1)

This function has as its variable (x) which is the capacity of the plant in m3 / d (cubic meters per day). The conversion from units to L / s is performed:

Función de costo para nanofiltración (2)

Additional modifications to this function correspond to the correction of costs per year, with the CCI ENR index for 2013, to obtain A3. Then part B2 related to the elasticity index is added. This is done in the same way as explained in the article Cost functions — General.

Based on the above, the following is the function obtained:

Función de costo para nanofiltración (3)

Bibliography

  1. Review of cost versus scale: water and wastewater treatment and reuse processes Guo, T., Englehardt, J., & Wu, T. 2013

    Information on the cost of potentially useful unit treatment processes for the direct reuse of drinking water versus system capacity

References